Interlaboratory Proficiency testing: Metals in natural waters


Distribution Schedule 2025



Round Registration
deadline
Despatch
samples
Reporting
deadline
Final Report

Round March 2025 07/02/2025 24/02/2025 21/03/2025 07/04/2025
Registration Deadline: 07/02/2025

Round October 2025 26/09/2025 13/10/2025 07/11/2025 24/11/2025
Registration Deadline: 26/09/2025
eCommerce Qualitycheck 2025 - Order Online


Scope of the Interlaboratory Proficiency Testing

The scope of this proficiency testing is the evaluation of the performance of laboratories for the determination of the metals in natural waters (ex. drinking water, mineral water, groundwater, etc.).

Interlaboratory proficiency testing organized in accordance with the standard ISO/IEC 17043:2010 - Conformity assessment — General requirements for proficiency testing.

Parameters

  • Aluminum (Al)
    (50 - 500 microg/L)
  • Antimony (Sb)
    (1 - 50 microg/L)
  • Arsenic (As)
    (5 - 50 microg/L)
  • Barium (Ba)
    (500 - 3000 microg/L)
  • Beryllium (Be)
    (2 - 20 microg/L)
  • Boron (B)
    (100 - 2000 microg/L)
  • Cadmium (Cd)
    (1 - 20 microg/L)
  • Chromium (Cr)
    (10 - 200 microg/L)
  • Chromium VI (Cr VI) (1)
    (1 - 50 microg/L)
  • Cobalt (Co)
    (5 - 50 microg/L)
  • Copper (Cu)
    (50 - 2000 microg/L)
  • Iron (Fe)
    (50 - 1000 microg/L)
  • Lead (Pb)
    (1 - 100 microg/L)
  • Manganese (Mn)
    (10 - 100 microg/L)
  • Mercury (Hg)
    (0.5 - 10 microg/L)
  • Molybdenum (Mo)
    (15 - 150 microg/L)
  • Nickel (Ni)
    (5 - 100 microg/L)
  • Selenium (Se)
    (5 - 50 microg/L)
  • Silver (Ag)
    (1 - 100 microg/L)
  • Thallium (Tl)
    (1 - 10 microg/L)
  • Tin (Sn)
    (10 - 100 microg/L)
  • Vanadium (V)
    (10 - 200 microg/L)
  • Zinc (Zn)
    (50 - 1000 microg/L)
(1): Parameter included in Round October.

Proficiency test item:

  • 1 x 450 mL of the test material stabilized with nitric acid (up to pH<2U) ready to use for the determination of all metals except Cr VI and Mercury (Hg).
  • 1 x 1000 mL of the test material to be prepared from a matrix and a vial of the spiking solution for the determination of Cr VI.
  • 1 x 1000 mL of the test material to be prepared from a matrix and a vial of the spiking solution for the determination of Mercury (Hg).

NOTE: All the details for the preparation of the final test sample are included in the Guide Lines of the interlaboratory proficiency testing provided with the test samples.

ADDITIONAL TEST SAMPLES: For costs and availability of additional test samples contact Qualitycheck (e-mail sales@qualitychecksrl.com)


ANALYSIS

The test sample should be analysed under the same conditions and with the same procedures used for the routine samples in the laboratory including the quality control procedures.

For each measurand shall be reported one result.

ADDITIONAL RESULTS: Each participant can submit up to 5 results* for the same analyte, thus obtaining an evaluation of laboratory performance for different operators, instruments and/or test methods (e.g. operator 1/operator 2, instrument A/instrument B, etc..).

eCommerce Qualitycheck 2025
Order Online Proficiency Testing


    Did you find this page helpful?

    YesNo



    *: Only one result submitted by the laboratory will be included in the statistical treatment of data for the calculation of the Assigned Value and statistics of data of the analyte, to avoid that a single laboratory has a different statistical weight, depending on the number of its submitted results. The additional results are evaluated by assigning z-score values, using the Assigned Value and the Standard Deviation for Proficiency Assessment obtained from statistical treatment.